Study 36 of 48Oxytocin literatureInternational journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group · Observational2026

Perfusion response to treatment outcome: CEUS links oxytocin to HIFU efficacy prediction for uterine fibroids.

Oxytocin can induce significant perfusion changes in uterine fibroids, which may help predict the efficacy of HIFU treatment.

Read at International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia GroupAdd to compare

Where it sits

this study against the rest of the oxytocin corpus
2
Preclinical
33
Observational · this one
0
Open-label
8
Randomised
5
Reviews

Summary and findings

This study evaluated oxytocin-induced perfusion changes in uterine fibroids in 55 patients using contrast-enhanced ultrasound (CEUS) and assessed their predictive value for high-intensity focused ultrasound (HIFU) ablation efficacy. Patients received an intravenous oxytocin infusion at a dose of 0.10 U/ml over 10 minutes. The findings indicated significant differences in perfusion parameters between groups based on ablation efficacy.

How much of this paper we could read: full text read (0.80). We had a clear abstract, so the summary below closely tracks the paper. What this means →
APDT(Δt) was significantly longer in the ≥70% group at 16.76 ± 12.12 s, p<0.05.n=552026

Abstract

The authors’ words, as International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group supplied them

Objectives To evaluate oxytocin-induced perfusion changes in uterine fibroids using contrast-enhanced ultrasound(CEUS) and determine their predictive value for high-intensity focused ultrasound (HIFU) ablation efficacy. Methods Fifty-five patients (mean age 42.15 ± 5.34 years). with 78 uterine fibroids underwent oxytocin-enhanced HIFU therapy. CEUS was performed before and after intravenous oxytocin infusion (0.10 U/ml over 10 min). Perfusion changes were assessed using two parameters:(1) Arterial-phase Perfusion Delay Time difference (APDTΔt), defined as the time difference in enhancement onset of fibroids before and after oxytocin exposure; (2) Visual Perfusion Grading (VPG), based on relative contrast perfuse reduction of fibroids at the end of the arterial phase(Grade1:≤30%;Grade2:30-70%;Grade3:≥70%). Post-treatment contrast-enhanced pelvic MRI was used to calculate fibroid volume and non-perfused volume(NPV),from which ablation ratio was derived. Fibroids were dichotomized by ablation efficacy (≥70%vs < 70%), and correlation analyses and ROC curves were used to evaluate predictive performance. Results Fibroids in the <70% ablation group showed a mean APDT(Δt) of 8.32 ± 5.61s and 52.2%(12/23) VPG as Grade1. In the ≥70% group, APDT(Δt) was significantly longer (16.76 ± 12.12 s), and 54.5%(30/55) VPG were Grade3. Both APDT(Δt) and VPG differed significantly between groups (p < 0.05), Showing strong correlations with ablation ratio (r = 0.577 and r = 0.585; both p < 0.001). Thresholds of APDT(Δt) >3.5 s and VPG >1.5 yielded sensitivities of 83.6% and 87.3%, specificity of 65.2% and 52.3%, with AUCs of 0.791 and 0.725, respectively. Conclusion CEUS can effectively detect oxytocin-mediated perfusion changes in uterine fibroids. These changes are strongly associated with HIFU ablation outcomes, and in particular, Arterial-phase Perfusion Delay Time demonstrates robust predictive value for treatment efficacy.

Background

This paper addresses the relationship between oxytocin-induced perfusion changes in uterine fibroids and the efficacy of high-intensity focused ultrasound (HIFU) ablation. Prior research has indicated that perfusion changes may correlate with treatment outcomes, but specific predictive parameters have not been well established. Understanding these relationships is crucial for improving treatment strategies for uterine fibroids.

Methods

This study involved 55 patients with a mean age of 42.15 ± 5.34 years, all of whom had 78 uterine fibroids. Patients received an intravenous infusion of oxytocin at a dose of 0.10 U/ml over 10 minutes before undergoing HIFU therapy. The primary outcomes measured were Arterial-phase Perfusion Delay Time difference (APDTΔt) and Visual Perfusion Grading (VPG), assessed before and after oxytocin infusion.

Results

The primary endpoint showed that the mean APDT(Δt) was 8.32 ± 5.61s in the <70% ablation group, while it was significantly longer at 16.76 ± 12.12 s in the ≥70% group (p<0.05). The VPG results indicated that 52.2% of the <70% group were graded as Grade1, while 54.5% of the ≥70% group were graded as Grade3. Correlation analyses revealed strong correlations with ablation ratio (r=0.577 and r=0.585, both p<0.001).

Interpretation

The findings suggest that oxytocin-induced perfusion changes can predict HIFU ablation efficacy, with APDT(Δt) showing a robust predictive value. However, while the statistical significance is clear, the clinical relevance of these findings may be limited by the small sample size and reliance on surrogate endpoints. Further studies are needed to validate these results in larger populations and assess long-term outcomes.

Key findings

  • Fibroids in the <70% ablation group showed a mean APDT(Δt) of 8.32 ± 5.61s.
  • In the ≥70% group, APDT(Δt) was significantly longer at 16.76 ± 12.12 s.
  • 52.2% (12/23) of the <70% group had VPG as Grade1.
  • 54.5% (30/55) of the ≥70% group had VPG as Grade3.
  • Thresholds of APDT(Δt) >3.5 s yielded a sensitivity of 83.6% and specificity of 65.2%.
  • Thresholds of VPG >1.5 yielded a sensitivity of 87.3% and specificity of 52.3%.

Limitations

  • small sample size of 55 patients
  • reliance on surrogate endpoints for efficacy prediction
  • no long-term follow-up reported
  • single-site study may limit generalizability

Elsewhere in the Oxytocin corpus

BA predictive model for caesarean section during labour in women with pre-eclampsiabiorxiv-preprint · 2026 · n=627 · AUC of 0.601 (95% CI 0.556–0.646, p < 0.001)HumanBCompartment-specific transcriptional programs of the gravid human myometrium underlie labor and uterine atonybiorxiv-preprint · 2023 · n=15 · Not reported in abstract.HumanBCircadian Chronobiology of Cervical Ripening Balloon Insertion: Effects on Labor Progression and Maternal Outcomesbiorxiv-preprint · 2026 · 5.5% postpartum hemorrhage in study group 1 vs. 16.4% in study group 2, P=0.040.HumanBHypothalamic Neurochemical and Microglial Suppression in Long-Standing Human Hibernation-Like Syndrome.Neuropathology and applied neurobiology · 2023 · n=1 · Not reported in abstract.HumanCThyroid hormone excess targeted to oxytocin neurons disrupts oxytocin physiology without impacting behavior.Psychoneuroendocrinology · 2026 · Not reported in abstract.AnimalACharacterizing vaginal misoprostol induction in individuals with and without severe obesity.The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians · 2026 · n=1322 · Individuals with BMI ≥ 40 kg/m² had an adjusted mean difference of 3.5 hours longer total duration of labor, 95% CI 1.9-4.8.Human