124Iodine Evuzamitide Positron Emission Tomography in Patients with Established or Suspected Cardiac Amyloidosis.

124I-evuzamitide PET imaging shows high diagnostic accuracy for cardiac amyloidosis, with 100% sensitivity and specificity in this study.

Read at JACC. Cardiovascular imagingAdd to compare

Where it sits

this study against the rest of the evuzamitide corpus
0
Preclinical
8
Observational · this one
0
Open-label
1
Randomised
5
Reviews

Summary and findings

This study assessed the performance and safety of 124I-evuzamitide PET/MRI in patients with known or suspected cardiac amyloidosis. A total of 126 patients were evaluated, with 87 (69%) receiving a diagnosis of cardiac amyloidosis. The study reported 100% sensitivity and specificity for the diagnostic scans.

How much of this paper we could read: full text read (0.90). We had a clear abstract, so the summary below closely tracks the paper. What this means →
Mean LV/blood pool standardized uptake value ratio (SUVRmean) was 1.89 ±0.29 in patients with CA and 0.91 ±0.15 in patients without CA, p<0.001.2026

Abstract

The authors’ words, as JACC. Cardiovascular imaging supplied them

Background 124I-evuzamitide is a pan-amyloid positron emission tomography (PET) radiotracer. Objectives We conducted an open-label study to assess the performance and safety of 124I-evuzamitide PET/magnetic resonance imaging (MRI) in patients with known or suspected cardiac amyloidosis (CA). Methods Consecutive patients with suspected or known CA, were invited to participate in the trial and underwent imaging with 124I-evuzamitide (mean administered activity 1.05±0.02 mCi), using PET/MRI preferentially, and PET/computed tomography (CT) as an alternative. A positive scan was defined visually as tracer uptake in the left ventricular (LV) myocardium greater than blood pool activity by 3 expert readers. Equivocal scans were prespecified to be classified as negative (except for inter-reader agreement). Results A total of 126 patients (mean age 71.6 ± 10.6 years, 76.2% male) completed the 124I-evuzamitide PET/MRI (n=123) or PET/CT (n=3) scan, where 87 (69%) received a diagnosis of CA. All patients with CA had a visually positive scan and all patients without CA had a visually negative scan by all 3 readers (100% sensitivity and specificity). There was disagreement on 5 patients who were graded as equivocal or negative scans (Fleiss' Kappa 0.94, none received CA diagnosis). Quantitatively, mean LV/blood pool standardized uptake value ratio (SUVRmean) was 1.89 ±0.29 and 0.91 ±0.15, in patients with and without CA, respectively (p<0.001). 124I-evuzamitide was well-tolerated without significant tracer-related adverse events. Conclusion 124I-evuzamitide PET provides excellent diagnostic accuracy in patients known or suspected to have cardiac amyloidosis, and might provide a single upstream assessment for the presence or absence of cardiac amyloidosis.

Elsewhere in the Evuzamitide corpus

B124I-Evuzamitide Positron Emission Tomography/Computed Tomography for Diagnosing Cardiac Amyloidosis: The REVEAL Nonrandomized Clinical Trial.JAMA · 2026 · Overall sensitivity was 94% (95% CI, 85%-98%; P < 0.001).HumanDDiagnostic value of positron emission tomography using amyloid-binding radiotracers for cardiac amyloidosis: a systematic review and meta-analysis.European heart journal. Imaging methods and practice · 2026 · Summary sensitivity of 0.91 (95% CI 0.83-0.96), n=577.reviewDDelivering the blueprint: Advances and challenges in mRNA therapeutics for the respiratory system.International journal of pharmaceutics: X · 2026reviewBPatient and clinician experiences of language barriers in Qatar's multilingual public mental health care: a qualitative study.International journal of qualitative studies on health and well-being · 2026HumanBAI-assisted MALDI-TOF MS for identifying carbapenem resistance in clinical Acinetobacter baumannii isolates.Emerging microbes & infections · 2026 · n=191 · Accuracy of 96.36% in distinguishing CRAB from CSAB.HumanDUtero-placental calcium and magnesium ion channels: A systematic review of obstetric implications of their alterations.Channels (Austin, Tex.) · 2026 · Not reported in abstract.review